Ultra Start 450 SERIES Manuel d'installation Page 191

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 300
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 190
Publication 1398-5.2 – PDF 1997
Maintenance and Troubleshooting 11-9
If you see the character on the screen remove the jumper between
pins 2 and 3, close the Windows Terminal and restart
ULTRA Master.
If the character does not echo back on the screen, do the
following:
Disconnect the cable from your PC.
Jumper Pins 2 and 3 on the communication port of the PC.
Type any character on the keyboard.
– If the character echoes back, the communication port is OK
and the cable or the connectors are defective. Replace the
communication cable assembly.
– If the character did not echo back, the communication port
is defective. Replace the communication port.
Testing Digital Outputs
This test verifies the functionality of the selectable outputs.
Test equipment requirements are:
A PC running ULTRA Master
A multimeter.
This test assumes there are no error codes displayed, and the I/O
power supply (internal for 1398-DDM-010, -020, -030 or -075 and
external for 1398-DDM-005, -005X, -009, -009X, -019 or -019X) for
the drive is connected correctly.
1. Disable the drive by opening the switch connecting J1-26 and J1-
20.
2. From the Drive Window select the
Output Diagnostics command
icon.
3. Verify each of the Digital Outputs in the Output Diagnostics win-
dow registers the appropriate readings on a multimeter when the
following values are set:
A. Drive Ready box, then measure the resistance between J1-24
and J1-25.
Note: Disconnect the outputs from any external hardware while per-
forming this test.
Note: This test assumes that I/O power is 24 VDC.
Vue de la page 190
1 2 ... 186 187 188 189 190 191 192 193 194 195 196 ... 299 300

Commentaires sur ces manuels

Pas de commentaire