Chapter 8 Diagnostics and Troubleshooting 411
Environmental Failures
The environmental monitoring subsystem monitors the temperature of the system as
well as the operation of the fans and power supplies. For more information on the
environmental monitoring subsystem, see “Environmental Monitoring and Control”
on page 46.
In response to an environmental error condition, the monitoring subsystem
generates error messages that are displayed on the system console and logged in the
/var/adm/messages file. These error messages are described in the following
table.
Message Type Description
CPU %d OVERHEATING!!! Warning After this warning message, the system
automatically shuts down. Indicates that the
temperature as measured at the CPU has
reached 80 degrees C. The value %d
identifies the CPU that overheated.
Cannot read Power
Supply Temps!!
Advisory Indicates that the power supply is not
properly seated or faulty.
A Power Supply is close
to OVERHEATING!!!
Advisory Indicates that the temperature as measured
at the power supply has exceeded 95
degrees C.
Power Supply %d
OVERHEATING!!!
Warning After this message,the system automatically
shuts down. Indicates that the temperature
as measured at the power supply has
reached 100 degrees C. The value %d
identifies the power supply that overheated.
Power Supply %d NOT
okay.
Advisory Indicates that there is something wrong
with the AC input to the supply. The system
may shut down abruptly if the power
supply shuts off. The value %d identifies the
power supply.
Power Supply %d
Overloaded
Advisory Indicates that the limit of the +3.3 V, +5 V or
+12 V power supply output has been
exceeded. The system may shut down
abruptly if the power supply shuts off. The
value %d identifies the power supply.
Power Supply %d load
share err
Advisory Indicates that the power supplies in an N+1
configuration are not sharing the load
equally. The system may shut down
abruptly if a power supply shuts off. The
value %d identifies the power supply.